  • Product overview of three-phase 200V isolation transformers for Japanese equipmentThe SG-F series of three-phase dry isolating transformers for Japanese equipment are a new generation of energy-saving power transformers developed and produced by our
  • Hotline:021-57715555   13817716438
Product Description

Product overview of three-phase 200V isolation transformers for Japanese equipment

The SG-F series of three-phase dry isolating transformers for Japanese equipment are a new generation of energy-saving power transformers developed and produced by our factory on the basis of referring to similar products and combining with my country’s national conditions. The transformers range from 100VA to 2000KVA and comply with IEC439, GB5226 and other standards. The winding adopts a whole-row winding method; the transformer is vacuum dipped to make the insulation grade of the transformer reach F or H grade, and the product performance reaches the advanced level at home and abroad.SG-F series three-phase dry-type isolation transformers are widely used in circuits with AC 50Hz to 60Hz and voltages below 3300V. They are used in power supplies for equipment imported from Japan, Taiwan, South Korea, the United States, precision machine tools, mechanical electronic equipment, medical equipment, rectifiers, lighting, etc. .The various input and output voltages of the product, the connection group, the number and position of the adjustment taps (usually ±5%), the distribution of winding capacity, the secondary single-phase winding equipment, the use of rectifier circuits, whether it is required to bring The shell, etc., can be carefully designed and manufactured according to user requirements.

Product features of three-phase 200V isolation transformer for Japanese equipment

The establishment of a new neutral line-grounding in the isolation transformer can relieve the common mode interference and other neutral lines in the power grid. The isolation transformer converts the three-wire delta connection into a four-wire Yo system, and shielding further eliminates the high-frequency pulse interference coupled by the transformer. And noise, although the shielded isolation transformer can effectively prevent various NG interference (pulse and high-frequency noise), the transformer must be properly grounded and very strict, otherwise the anti-common mode interference will be ineffective.The company can design and produce high-quality isolation transformers for customers.

Features and advantages of a three-phase 200V isolation transformer for Japanese equipment:

ØHigh isolation

ØN-G performance is good

ØHighly common mode interference suppression

Ø Convert △ to Y or Y to △

ØEasy to change the voltage tap

ØDesigned according to user's special performance requirements

Technical index of three-phase 200V isolation transformer for Japanese equipment

1. Input rated voltage: three-phase 380V or single-phase 380V or single-phase 220V

2. Output rated voltage: three-phase 220V/200V/208V/230V/480V or single-phase 110V/120V/127V/

3. Working frequency: 50Hz-60Hz

4. Efficiency: ≥95%

5. Temperature rise: <60K

6. Waveform distortion: <0.1%

7. High voltage test: 2500V, no breakdown in 1 minute

8. Insulation resistance: winding insulation resistance to ground ≥500M ohms, primary to secondary insulation resistance ≥ 500M ohms


Appearance and installation dimensions of three-phase 200V isolation transformer for Japanese equipment

model Capacity (KVA) Output voltage (V) Connection group number Dimensions (mm)
enter Output Account opening Protective
Bmax Dmax Emax Bmax Dmax Dmax
SG-F-0.15 0.15 660
380
220
380
220
200
127
V/V
Y/yno(Y/yo)
Y/d(Y/)
D/Y(△/Y)
Y/d(△/△)
200 105 140 260 180 160
SG-F -0.3 0.3 180 110 180 260 180 160
SG-F -0.5 0.5 180 115 180 260 200 120
SG-F -0.75 0.75 230 130 200 260 250 260
SG-F-1 1 230 140 200 315 200 260
SG-F-1.5 1.5 230 155 200 355 290 280
SG-F-2 2 270 165 250
SG-F -2.5 2.5 270 175 250 370 290 300
SG-F-3 3 270 185 250
SG-F-4 4 300 180 285 510 400 550
SG-F-5 5 300 200 285
SG-F-10 10 370 210 240 560 430 600
SG-F-15 15 420 245 390 600 440 620
SG-F-20 20 540 320 450 650 440 650
SG-F-30 30 540 380 480 870 500 780
SG-F-40 40 750 350 520 960 550 810
SG-F-50 50
SG-F-60 60 800 450 650 1000 810 810
SG-F-80 80
SG-F-100 100 860 450 650 1050 810 810
SG-F-125 125 860 500 700
SG-F-160 160 950 600 800
SG-F-200 200 1000 680 850
SG-F-250 250 1050 700 850

Use conditions of three-phase 200V isolation transformer for Japanese equipment

1. Applicable altitude: ≤5000m

2. Ambient temperature: -15℃~+45℃

3. Relative humidity: ≤90%

4. There should be no gas, steam, chemical deposits, dirt, conductive dust and other explosive, flammable and corrosive substances that seriously affect the insulation strength of the transformer.

5. Anyone that does not meet the above conditions of use should be determined through consultation with us.