  • Category:Inverter output reactor
  • product description Output AC reactors are used on the load side of the inverter, and the motor current flows through these reactors. The output AC reactor compensates for the capacitive charge reversal current of long cables, and in the case of lon
  • Hotline:021-57715555   13817716438
Product Description

product description

Output AC reactors are used on the load side of the inverter, and the motor current flows through these reactors.

The output AC reactor compensates for the capacitive charge reversal current of long cables, and in the case of long motor cables, can limit the dv/dt of the motor terminals.

Performance characteristics

The iron core is made of high-quality oriented silicon steel sheet. The core column is divided into uniform small pieces through multiple air gaps. The air gap adopts high-temperature and high-strength adhesive glue to closely bond each small section of the core column with the upper and lower iron yokes. The use of high-quality anti-rust paint spraying process solves the problem of rust on the surface of the iron core of the reactor. Noise and vibration are greatly reduced during operation.

Weihao reactors all adopt the vacuum dipping process and are cured by high temperature heat baking. The coil has good insulation performance, high overall mechanical strength and good moisture resistance. The coil adopts F, H class insulation system, which greatly improves the reliability of long-term operation. Low temperature rise, low loss, low cost and high comprehensive utilization rate.

product description

Reduce the noise of the motor and reduce the eddy current loss.

Reduce leakage current caused by input high harmonics.

Used for smoothing filtering, reducing transient voltage dv/dt and prolonging motor life.

Protect the power switching devices inside the inverter.

technical parameter

Rated working voltage: 400V/380V/50Hz or 660V/50Hz

Rated operating current: 5A to 1600A@40℃

Dielectric strength: iron core-winding 3500VAC/50Hz/10mA/10s without arcing breakdown

Insulation resistance: 1000VDC insulation resistance ≥ 100MV

Reactor noise: less than 65dB

Protection class: IP00

Insulation class: above class F

Product performance standards

IEC289:1987 Reactor

GB10229-88 Reactor (eqv IEC289:1987)

JB9644-1999 Reactor for Semiconductor Electric Transmission

Output AC reactor 0.5%-1%:

Output AC reactor 2%:

Installation size


Inverter power ( KW )

model

Inductance ( mH )

Dimensions (mm)

Installation size (mm)

0.75

OCL-5

1.4

110*110*130

90*65

1.5

OCL-5

1.4

110*110*130

90*65

2.2

OCL-10

1.0

110*110*130

90*65

3.7

OCL-15

0.47

110*110*130

90*65

5.5

OCL-15

0.47

155*130*130

95*60

7.5

OCL-20

0.35

155*130*130

95*80

11

OCL-30

0.23

155*135*130

95*80

15

OCL-40

0.18

155*135*130

95*80

18

OCL-50

0.14

155*135*130

95*80

twenty two

OCL-60

0.12

195*130*165

120*70

30

OCL-80

0.087

195*130*165

120*70

37

OCL-110

0.078

195*130*165

120*70

45

OCL-125

0.064

195*135*165

120*90

55

OCL-150

0.056

250*170*230

180*85

75

OCL-200

0.035

250*170*230

180*85

93

OCL-250

0.028

250*170*230

180*85

110

OCL-275

0.025

250*170*230

180*85

132

OCL-330

0.021

290*190*250

215*100

160

OCL-450

0.016

290*190*250

215*100

185

OCL-500

0.014

290*190*250

215*100

200

OCL-510

0.0137

320*220*320

245*110

220

OCL-540

0.013

320*220*320

245*110

250

OCL-625

0.011

320*240*320

245*130

280

OCL-700

0.010

320*240*320

245*130

315

OCL-800

0.0088

320*240*320

245*130

375

OCL-1000

0.007

385*250*395

260*175

400

OCL-1100

0.0064

385*250*395

260*175