Single-phase 60Hz variable frequency power supply
- Category:Single-phase inverter power supply
- Single-phase 60Hz variable frequency power supply product introduction: After joining the WTO, China's economy is in line with the world, bringing opportunities to export electrical appliance manufacturers. Since the power grid ind
- Hotline:021-57715555 13817716438
Single-phase 60Hz variable frequency power supply product introduction:
After joining the WTO, China's economy is in line with the world, bringing opportunities to export electrical appliance manufacturers. Since the power grid indicators of various countries in the world are not uniform, the production of export products requires the power grid to simulate the power grid conditions of different countries and ensure stability. In the past, the voltage regulator was used for voltage regulation, the voltage regulator was used to stabilize the voltage, and the generator was subjected to secondary frequency conversion. The power consumption was large, the noise was loud, and the poor stability was gradually replaced by the frequency conversion power supply. AC60 program-controlled variable frequency power supply is specially designed and manufactured for import and export electrical products transformation, variable frequency test power supply, can provide the world's standard grid voltage and frequency, output voltage, frequency stepless digital adjustable, stable and pure waveform, eliminate grid interference, It is suitable for voltage and frequency conversion test of export electrical products; laboratory, measurement room, etc. for various precision tests, and as a power supply for 60Hz equipment.
Features of single-phase 60Hz variable frequency power supply:
1. With over-voltage, over-current, short-circuit and overheating warning devices
2. 16-bit microprocessor control, intelligent, flexible and convenient operation
3. Low distortion interference, completely isolated input/output, safe and reliable
4. Unique instantaneous value control, small waveform distortion and high control accuracy
5. The dynamic response is extremely fast. When the load changes from 0 to 100%, the steady-state response time is less than 0.1S.
6. Provide standard grid voltage, frequency and simulation test of various electrical products in various countries in the world
7. No radiation interference, small harmonic components, and special treatment, no dry winding
8. The efficiency is as high as 85% or more, and it is suitable for a wide range of loads, including inductive, capacitive and resistive loads.
9. Original imported German Siemens IGBT high frequency inverter and movement, stable and reliable
10. Output voltage: low-grade: 0-150V, high-grade: 0-300V continuously adjustable
11. One machine is multi-purpose, and the meter and source are combined into one: the output has a 0.5-level voltage, current, frequency, power/power factor meter
Executive standard: "GB7260-87 Uninterruptible Power Supply Equipment" "Q/01AK001-2005 Programmable Frequency Conversion Voltage Regulation Power Supply"
Main parameter table of single-phase 60HZ variable frequency power supply
Single-phase 60Hz variable frequency power supply |
||||||
model |
Ay60-11005 |
Ay60-1101 |
Ay60-1103 |
Ay60-1105 |
Ay60-31010 |
|
capacity |
500VA |
1KVA |
3KVA |
5KVA |
10KVA |
|
output Current |
low grade |
4.2A |
8.4A |
25A |
42A |
84A |
High-end |
2.1A |
4.2A |
12A |
21A |
42A |
|
Input voltage |
220V/380V ± 10% , 50hz |
|||||
input phase |
Single-phase / three-phase four-wire |
|||||
The output voltage |
Low-grade 0 ~ 150V continuously adjustable and high-grade 0-300V continuously adjustable |
|||||
Output frequency |
Fixed frequency 50 Hz/60 Hz/100 Hz/200Hz and frequency modulation 40.0Hz ~ 200.0Hz continuously adjustable |
|||||
Load regulation rate |
≤± 1% |
|||||
Frequency Stability |
Fixed frequency ≤± 0.01% ; frequency modulation ≤± 0.1% |
|||||
Three-phase unbalance |
Phase 120 °± 2 °; phase difference <3% of rated value |
|||||
Waveform distortion |
THD ≤ 2% |
|||||
Reaction time |
≤ 2mS |
|||||
show Precision |
4 -digit frequency table |
Resolution 0.1Hz |
||||
4 digit voltmeter |
Resolution 0.1v |
|||||
4 digit ammeter |
Resolution 0.01A |
|||||
4 -digit power meter |
Resolution 0.1w |
|||||
Communication interface (option) |
RS232 or RS485 optional |
|||||
Protocol |
MODBUS communication protocol |
|||||
Protective function |
Over voltage, over current, over temperature, overload, short circuit protection and automatic alarm |
|||||
Insulation reactance |
20M 500VDC [Omega |
|||||
Withstand voltage insulation |
1800Vac/5mA/ 1min |
|||||
cooling method |
Forced fan cooling |
|||||
Operating temperature |
-20 ℃ -40 ℃ |
|||||
Relative humidity |
0-90% (non-condensing state) |
|||||
Altitude |
1500 meters |
|||||
structure |
19 inch rack mount |
Cabinet (W×D×H) mm |
||||
size |
3U |
5U |
560 × 350 × 600 |
660 × 400 × 700 |
Single-phase 60Hz variable frequency power supply |
|||||||
model |
Ay60-31015 |
Ay60-31020 |
Ay60-31030 |
Ay60-31045 |
Ay60-31060 |
Ay60-31100 |
|
capacity |
15KVA |
20KVA |
30KVA |
45KVA |
60KVA |
100KVA |
|
output Current |
low grade |
126A |
168A |
250A |
375A |
500A |
840A |
High-end |
63A |
84A |
125A |
188A |
250A |
420A |
|
Input voltage |
380V ± 10% , 50hz |
||||||
input phase |
Three-phase four-wire |
||||||
The output voltage |
Low-grade 0 ~ 150V continuously adjustable and high-grade 0-300V continuously adjustable |
||||||
Output frequency |
Fixed frequency 50 Hz/60 Hz/100 Hz/200Hz and frequency modulation 40.0Hz ~ 200.0Hz continuously adjustable |
||||||
Load regulation rate |
≤± 1% |
||||||
Frequency Stability |
Fixed frequency ≤± 0.01% ; frequency modulation ≤± 0.1% |
||||||
Three-phase unbalance |
Phase 120 °± 2 °; phase difference <3% of rated value |
||||||
Waveform distortion |
THD ≤ 2% |
||||||
Reaction time |
≤ 2mS |
||||||
show Precision |
4 -digit frequency table |
Resolution 0.1Hz |
|||||
4 digit voltmeter |
Resolution 0.1v |
||||||
4 digit ammeter |
Resolution 0.01A |
||||||
4 -digit power meter |
Resolution 0.1w |
||||||
Communication interface (option) |
RS232 or RS485 optional |
||||||
Protocol |
MODBUS communication protocol |
||||||
Protective function |
Over voltage, over current, over temperature, overload, short circuit protection and automatic alarm |
||||||
Insulation reactance |
20M 500VDC [Omega |
||||||
Withstand voltage insulation |
1800Vac/5mA/ 1min |
||||||
cooling method |
Forced fan cooling |
||||||
Operating temperature |
-20 ℃ -40 ℃ |
||||||
Relative humidity |
0-90% (non-condensing state) |
||||||
Altitude |
1500 meters |
||||||
Dimensions (W×D×H) mm |
830 × 450 × 1100 |
1100 × 480 × 1200 |