PRODUCT
Tel:400-685-8582
Tel:+86-21-57715555
+86-21-37831986
Fax:+86-21-37831846
Phone:13817716438
Email:weho@chinaweho. com
Address:Building 2, No.8 Nanle Road, Songjiang District, Shanghai
JBK4-WBK machine tool control transformer
- Category:JBK series transformers
- product description JBK5JBK6 series machine tool control transformers are the latest transformer series introduced by our company from Germany. On the basis of domestic JBK3 series machine tool control transformers, after years of further absorbing
- Hotline:021-57715555 13817716438
product description
JBK5JBK6 series machine tool control transformers are the latest transformer series introduced by our company from Germany. On the basis of domestic JBK3 series machine tool control transformers, after years of further absorbing foreign similar products, and optimizing the terminal structure of foreign advanced methods, the terminal and the skeleton are combined in At the same time, the protection level is increased to IP2LX to prevent accidental contact with the circuit. Using domestic IT cooling wiring terminals, the wiring method can improve the wiring density.
The connection between the silicon steel sheet and the silicon steel sheet of the transformer, and the connection between the silicon steel sheet and the bottom plate are all welded by argon welding, forming a whole, which is simple and clear, especially the bottom plate is formed at one time, and the installation size is more accurate than the JBK3 series Corrosion alloy material greatly improves the reliability of grounding performance and comprehensively improves product quality. This product complies with VDE0550, IEC204-1, IEC439, JB5555, GB5226 and other relevant international and national standards, and has won the European Community: "CE" demonstration , the United States "UL", can be used interchangeably with foreign products.
JBK5 series machine tool control transformers are suitable for AC 50Hz-60Hz, the input voltage does not exceed 500V, and the output rated voltage does not exceed 220V.
Models and what they mean
Shape and installation dimensions
model | Bmax | Dmax | Emax | Mounting hole distance | Mounting hole K or K×J | Fmax | Remark | |
A | C | |||||||
JBK5/6-40, 63VA | 78 | 72 | 90 | 56±0.15 | 46±0.125 | 4.6 | 1.2 | |
JBK5/6-100VA | 85 | 88 | 96 | 64±0.15 | 62±0.15 | 4.6 | 1.2 | |
JBK5/6-160VA | 96 | 92 | 106 | 84±0.175 | 73.5±0.5 | 5.5 | 1.5 | |
JBK5/6-250VA | 96 | 100 | 106 | 84±0.175 | 85±0.175 | 5.8 | 1.5 | |
JBK5/6-400VA | 120 | 100 | 122 | 93±0.175 | 84±0.175 | 5.8 | 2 | |
JBK5/6-630VA | 150 | 114 | 140 | 125±0.2 | 92±0.175 | 7 | 2 | |
JBK5/6-800VA | 150 | 125 | 142 | 125±0.2 | 105±0.2 | 7 | 2 | |
JBK5/6-1000VA | 160 | 195 | 142 | 140±0.2 | 158±0.2 | 12 | 3 | horizontal |
JBK5/6-1000VA | 168 | 130 | 155 | 138±0.2 | 105±0.2 | 15 | 2 | vertical |
JBK5/6-1600VA | 184 | 225 | 145 | 155±0.2 | 180±0.2 | 12 | 3 | horizontal |
JBK5/6-1600VA | 168 | 140 | 155 | 138±0.2 | 116±0.2 | 15 | 2 | vertical |
JBK5/6-2500VA | 250 | 200 | 152 | 165±0.2 | 210±0.23 | 12 | 4 |
Main technical parameters JBK5
Model parameters |
Rated capacity (VA) |
Efficiency % |
Signal winding (%) |
Control winding (%) |
Signal winding (%) |
Control winding (%) |
Rated input voltage (V) |
Rated output voltage (V) |
Remark |
JBK5/6-40 | 40 | The capacity distribution of each winding can be manufactured according to user requirements | |||||||
JBK5/6-63 | 63 | 80 | AC220(127)110 Control | ||||||
JBK5/6-100 | 100 | 6≥Um>5 | 95%~105% | ||||||
JBK5/6-160 | 160 | 12≥Um>10 | UH | AC380±5% | 48 | ||||
JBK5/6-250 | 250 | 85 | 6 or 12 | 1.1Um | 36 | ||||
JBK5/6-400 | 400 | 24 Lighting or Control | |||||||
JBK5/6-6300 | 630 | AC220±5% | |||||||
JBK5/6-800 | 800 | ||||||||
JBK5/6-1000 | 1000 | 90 | 12 | ||||||
JBK5/6-1600 | 1600 | 6≥Um>4.5 | 6 Signals | ||||||
JBK5/6-2500 | 2500 | 12≥Um>9 |
Conditions of Use
1. Applicable altitude: ≤5000m
2. Ambient temperature: -15℃~+45℃
3. Relative humidity: ≤90%
4. There should be no gas, steam, chemical deposition, dirt, etc. Conductive dust and no other explosive, flammable and corrosive substances.
5. Those that do not meet the above conditions of use should be negotiated with us.