TSGC TDGC Contact Regulator

PRODUCT

CONTACT US

Tel:400-685-8582

Tel:+86-21-57715555
          +86-21-37831986

Fax:+86-21-37831846

Phone:13817716438

Email:weho@chinaweho. com

Address:Building 2, No.8 Nanle Road, Songjiang District, Shanghai

TSGC2 (J) three-phase contact voltage regulator

TSGC2 (J) three-phase contact voltage regulator TSGC2 (J) three-phase contact voltage regulator TSGC2 (J) three-phase contact voltage regulator

TSGC2 (J) three-phase contact voltage regulator

  • Category:TSGC TDGC Contact Regulator
  • Scope of application TDGC2J and TSGC2J series products are the fourteenth batch of energy-saving products in the electromechanical industry. This product has the characteristics of undistorted waveform, small size, light weight, high efficiency, c
  • Hotline:021-57715555   13817716438
Product Description

Scope of application



TDGC2J and TSGC2J series products are the fourteenth batch of energy-saving products in the electromechanical industry. This product has the characteristics of undistorted waveform, small size, light weight, high efficiency, convenient use and reliable operation. Its performance is more superior and can be widely used in industrial (such as chemical industry, metallurgy, instrumentation, electromechanical manufacturing, light industry, etc.), scientific experiments, public equipment, household appliances, to achieve voltage regulation, temperature control, speed regulation, dimming and power control.


Models and what they mean


Working principle and structure

★Working principle The autotransformer whose turns ratio of the voltage regulator can be continuously adjusted, when the handwheel is turned, it slides on the polished surface of the coil with the help of a movable brush, and the turns of the lights are changed, thereby making the output voltage Smoothly adjustable from zero to maximum.

★Voltage regulating structure Single-phase below 7KVA is a unit structure, consisting of coil, brush, handwheel, dial, base, cover, etc.: Three-phase and single-phase large-capacity voltage regulators above 10KVA are composed of several same specifications. Units are assembled.

The main technical parameters are shown in the table below


model Rated capacity (KVA) Phase Rated frequency(Hz) Rated input voltage (V) Output voltage range (V) Rated input current (A)
TDGC2J-0.5 0.5 1 50 220 0~250 2
TDGC2J-1 1 1 50 220 0~250 4
TDGC2J-2 2 1 50 220 0~250 8
TDGC2J-3 3 1 50 220 0~250 12
TDGC2J-5 5 1 50 220 0~250 20
TDGC2J-7 7 1 50 220 0~250 28
TDGC2J-10 10 1 50 220 0~250 40
TDGC2J-15 15 1 50 220 0~250 60
TDGC2J-20 20 1 50 220 0~250 80
TDGC2J-30 30 1 50 220 0~250 120
TDGC2J-40 40 1 50 220 0~250 160


model Rated capacity (KVA) Phase Rated frequency(Hz) Rated input voltage (V) Output voltage range (V) Rated input current (A)
TSGC2J-3 3 3 50 380 0~430 4
TSGC2J-6 6 3 50 380 0~430 8
TSGC2J-9 9 3 50 380 0~430 12
TSGC2J-15 15 3 50 380 0~430 20
TSGC2J-20 20 3 50 380 0~430 27
TSGC2J-30 30 3 50 380 0~430 40
TSGC2J-40 40 3 50 380 0~430 54

Overall installation dimensions and see the table below

model Outline and installation dimensions (mm) Weight(Kg)
L1 L2 H H2 h 12 3.85
TSGC2J-0.5 150 124 174 142 20 12
TDGC2J-1 197 187 200 145 33 12 10.0
TDGC2J-2 240 225 208 148 33 20 13.8
TDGC2J-3 269 255 208 148 33 20
TDGC2J-5 380 345 254 171 40 20 68.85
TDGC2J-10 414 345 420 330 51 20
TDGC2J-15 414 345 580 490 51 20
TDGC2J-20 414 345 580 490 51 20
TDGC2J-30 414 345 1160 970 51 20
TDGC2J-40 414 345 1160 970 51 20
TSGC2J-3 197 187 480 415 44 14.5
TSGC2J-6 240 225 485 420 44 14.5
TSGC2J-9 269 225 485 420 44 14.5
TSGC2J-15 380 345 580 490 51 20
TSGC2J-20 380 345 580 490 51 20
TSGC2J-30 414 345 1160 970 51 20
TDGC2J-20 414 345 1160 970 51 20

use and maintenance

★The terminals A and X of the single-phase voltage regulator are the input terminals, and the terminals a and x are the output terminals; the terminals A, B, and C of the three-phase voltage regulator are the input terminals, and the terminals a, b, and c are the output terminals. The O terminal is a star (Y-shaped) neutral point.

★The voltage regulator is divided into single-phase series and three-phase series

★For new installation or long-term shelving of different voltage regulators, a 500-volt megohmmeter must be used to measure the insulation resistance of the terminal to the shell before running, and the value should not be less than 2 megohms.

★The input power voltage should conform to the rated input voltage on the nameplate of the voltage regulator.

★When using, it should be noted that the load current does not exceed the rated value, otherwise the life of the voltage regulator will be reduced or even burned.

★The use of the voltage regulator should be checked frequently, and the contact surface between the coil and the brush should be kept clean.

★The voltage regulator is not allowed to be used in parallel.

★The voltage regulator must be well grounded: to ensure safe use.