PRODUCT
Tel:400-685-8582
Tel:+86-21-57715555
+86-21-37831986
Fax:+86-21-37831846
Phone:13817716438
Email:weho@chinaweho. com
Address:Building 2, No.8 Nanle Road, Songjiang District, Shanghai
Rectifier transformer
- Category:Rectifier transformer
- Product Usage JBKZ series rectifier transformers conform to electrical rectification standards. It is composed of cold-pressed socket machine tool control transformer, etc. After assembly, it constitutes a single-phase full-wave, rectified power su
- Hotline:021-57715555 13817716438
Product Usage
JBKZ series rectifier transformers conform to electrical rectification standards. It is composed of cold-pressed socket machine tool control transformer, etc. After assembly, it constitutes a single-phase full-wave, rectified power supply. The AC input is provided with ±5% adjustment, so that the AC voltage can be changed into a DC power supply device, which is suitable for the use of electrical components of CNC machine tools.
normal working conditions
★The upper limit of ambient air temperature does not exceed +40℃;
★ 24h average ambient air temperature does not exceed 30 deg.] C +;
★ ambient air temperature limit is not lower than -5 deg.] C;
★ elevation: the installation site altitude not exceeding 2,000 m;
★ Air conditions: relative humidity of the ambient air temperature +40°C does not exceed 50%, and the relative temperature can be higher at lower temperatures. The average maximum relative humidity in the wettest month is 90%, and the average minimum temperature in this month is +25°C, and taking into account due to temperature changes Condensation on the surface of the product occurred;
★Pollution degree: pollution degree is three;
★Installation category (overvoltage category): Installation category is III;
★Power supply voltage: The allowable deviation of power supply voltage is ±5%;
★Installation conditions: Install in a place without severe vibration and shock vibration.
Models and what they mean
Dimensions
Installation size
Size Model |
Bmax | Dmax | Emax | Hole spacing |
Mounting hole K×J |
F | |
A | C | ||||||
JBKZ-5 | 130 | 190 | 140 | 120 | 110 | 6×12 | 2 |
JBKZ-10 | 130 | 200 | 140 | 120 | 125 | 6×12 | 2 |
JBKZ-20 | 175 | 240 | 170 | 157 | 160 | 6×13 | 2 |
The main technical parameters
model | Output current DC(A) | Input current AC(A) | Output voltage (V) |
JBKZ-5 | 5 | 220.380 | twenty four |
JBKZ-10 | 10 | 220.380 | twenty four |
JBKZ-20 | 20 | 220.380 | twenty four |
Installation and maintenance
★The use of the rectifier transformer must meet the conditions specified in Article 2;
★Before installation, carefully check the parameters on the nameplate, and then install and use it
;
★ Avoid collision as much as possible during transportation, store in a dry and ventilated place, and do not get wet to ensure the performance and service life of the product.